Transformers

///Transformers
  • Features

    • Compact size
    • In-built open circuit and overload protection

    • Dimming/animating capabilities
    • Low voltage input, 12V

       

    PRODUCT DOWNLOADS

    For further technical information please download our Product data sheet.
    Product Enquiry
  • PRODUCT DOWNLOADS

    For further technical information please download our Product data sheet.
    Product Enquiry
  • Description

    The 5kV mini Electronic Transformer is a compact, electronic neon transformer with internal safety features that initiate when an open output, broken tube or excess load is detected.

    Features

    • black 2-pin plug and lead (input connection)
    • 1m high voltage lead (output connection)

    • internal overload power-off device
    • compact size

     

    Technical Information

    The 5kV mini Electronic Transformer is conveniently fitted with an overload power-off device.  This feature prevents the installer from damaging the transformer by putting too much glass into the circuit.  However, this feature may cause nuisance tripping if the transformer is loaded to just within the maximum limit (refer to data sheet).  This is due to the fact that the supply voltage and the load conditions will fluctuate slightly during operation.  To avoid this nuisance tripping, it is recommended to bench test the sign and transformer with an extra 300mm length of 15mm Argon (blue gas) filled tubing.  If the transformer does not shut down with this extra load, then you can be confident that the loading is correct. In case of automatic overload power-off, the transformer will then attempt to restart up to 3 times within 10 seconds.  Short bursts of power (flashing) are generated during these 10 seconds. To reset device: switch power off (for at least 10 seconds), correct the fault and then switch power back on.

    PRODUCT DOWNLOADS

    For further technical information please download our Product data sheet.
    Product Enquiry
  • Description

    The 8kV mini Multi Function Electronic Transformer is a compact, electronic neon transformer with internal safety features that initiate when an open output, broken tube or excess load is detected.  This transformer has function and speed control.

    Features

    • black 2-pin plug and lead (input connection)
    • 1m high voltage lead (output connection)

    • internal overload power-off device
    • compact size

     

    Technical Information

    The 8kV mini Electronic Transformer is conveniently fitted with an overload power-off device.  This feature prevents the installer from damaging the transformer by putting too much glass into the circuit.  However, this feature may cause nuisance tripping if the transformer is loaded to just within the maximum limit (refer to data sheet).  This is due to the fact that the supply voltage and the load conditions will fluctuate slightly during operation.  To avoid this nuisance tripping, it is recommended to bench test the sign and transformer with an extra 300mm length of 15mm Argon (blue gas) filled tubing.  If the transformer does not shut down with this extra load, then you can be confident that the loading is correct. In case of automatic overload power-off, the transformer will then attempt to restart up to 3 times within 10 seconds.  Short bursts of power (flashing) are generated during these 10 seconds. To reset device: switch power off (for at least 10 seconds), correct the fault and then switch power back on.

    PRODUCT DOWNLOADS

    For further technical information please download our Product data sheet.
    Product Enquiry
  • Description

    The 8kV mini Electronic Transformer is a compact, electronic neon transformer with internal safety features that initiate when an open output, broken tube or excess load is detected.

    Features

    • black 2-pin plug and lead (input connection)
    • 1m high voltage lead (output connection)

    • internal overload power-off device
    • compact size

     

    Technical Information

    The 8kV mini Electronic Transformer is conveniently fitted with an overload power-off device.  This feature prevents the installer from damaging the transformer by putting too much glass into the circuit.  However, this feature may cause nuisance tripping if the transformer is loaded to just within the maximum limit (refer to data sheet).  This is due to the fact that the supply voltage and the load conditions will fluctuate slightly during operation.  To avoid this nuisance tripping, it is recommended to bench test the sign and transformer with an extra 300mm length of 15mm Argon (blue gas) filled tubing.  If the transformer does not shut down with this extra load, then you can be confident that the loading is correct. In case of automatic overload power-off, the transformer will then attempt to restart up to 3 times within 10 seconds.  Short bursts of power (flashing) are generated during these 10 seconds. To reset device: switch power off (for at least 10 seconds), correct the fault and then switch power back on.

    PRODUCT DOWNLOADS

    For further technical information please download our Product data sheet.
    Product Enquiry
  •  

    Features

    • IP44 rated for external use
    • Resinblock Iron Core transformer
    • Epoxy resin body allows for optimum heat dissipation
    • Output voltage available in 2000-15000VAC (actual voltage is dependent on the load and will be equal to or less than the value marked on the transformer)
    • Underlid connections for both primary and secondary leads, plus earth
    • Input voltage of 240VAC, 50Hz
    • 30mA short circuit current
    • 24mA (recommended) operating/load current

    PRODUCT DOWNLOADS

    Product Enquiry
  • Features

    • For 30mA neon transformers
    • 250VAC, max. load 2.5A

    • Load range 100VA-450VA
    • To reset: remove power, correct fault, restore power (reset delay is 6 seconds)

    • Approx. 100x55x65mm dimensions
    • 1.8m lead
    • The Plug In Open Circuit Monitor is designed to switch off the supply to the neon transformer in the case of an open circuit occurring (eg. broken tube)
     

    PRODUCT DOWNLOADS

    For further technical information please download our Product data sheet.
    Product Enquiry